Part Number Hot Search : 
7442N H928S LM339P GP20B 00AXC SC9308P R1300 CENTRAL
Product Description
Full Text Search
 

To Download NTX0 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  radiometrix ltd., NTX0/nrx0 data sheet page 1 features  conforms to etsi en 300 220-3 (radio) and en 301 48 9-3 (emc) and fcc 95.201-95.225  standard frequency: 27.095mhz  data rates up to 5kbps  usable range over 1km @ 10mw  10/12.5khz channel spacing  feature-rich interface (rssi, analogue and digital baseband)  longer range compared to wide band fm modules applications  radio control (r/c) radio service under fcc part 95 subpart c  radio model control  telemetry and telecommand  wireless door entry systems  simple on/off switching  in-building environmental monitoring and control  security and fire alarms  vehicle/machinery controls technical summary transmitter ? NTX0  3 stage crystal controlled vcxo  supply 2.9v - 15v @ 20ma (10mw)  data bit rate: 5kbps max.  transmit power: +10dbm (10mw), 50mw (+17dbm) or100m w (+20dbm)  size: 43 x 15 x 8mm receiver ? nrx0  double conversion fm superhet  supply range: 2.9v - 15v @ 12ma  data bit rate: 5kbps max.  receiver sensitivity: -115dbm (for 12db sinad)  adjacent channel: -60dbm  blocking: -85db  size: 47 x 17 x 8mm evaluation platforms : nbek + sil carrier the 10khz channel nbfm NTX0 transmitter and nrx0 receiver operate on the licence exempt 27mhz srd hf allocation. these modules offer a low power, reliable data link in a radiometrix sil standard pin out and foot print. this makes the NTX0/nrx0 pair ideally suited to those low power applications where existing single frequency wideband uhf modules have insufficient range, and in parts of the world where other frequency bands are not appropriate figure 1: nrx0-27.095-5 NTX0-27.095-5 27mhz hf narrow band fm tx & rx hartcran house, 231 kenton lane, harrow, middlesex, ha3 8rp, england tel: +44 (0) 20 8909 9595, fax: +44 (0) 20 8909 223 3, www.radiometrix.com issue 1, 02 november 2012 NTX0 / nrx0
radiometrix ltd., NTX0/nrx0 data sheet page 2 functional description the NTX0 transmitter consists of a frequency modula ted (fm) voltage controlled crystal oscillator (vcx o) feeding a two stage amplifier and rf filter. operat ion can be controlled by the en (enable) line, the transmitter achieving full rf output typically with in 5ms of this line being pulled high. the rf outpu t is filtered to ensure compliance with the appropriate radio regulations and fed to the 50 antenna pin. the nrx0 module is a double conversion nbfm superhe t receiver capable of handling data rates of up to 5kbps. it will operate from a supply of 2.9v to 15v and draws 12ma when receiving. a signal strength ( rssi) output with greater than 60db of range is provided. the sil style nrx0 measures 47 x 17 x 8 mm excludi ng the pins. NTX0 transmitter 7 holes of 0.7mm dia. pin spacing 2.54mm (0.1") 1 2 3 4 5 6 7 8mm 43mm 15mm 15.24mm (0.6") 1 = rf gnd 2 = rf out 3 = rf gnd 4 = en 5 = vcc 6 = 0v 7 = txd NTX0 32mm 23.5mm figure 2: NTX0 pin-out and dimension user interface NTX0 pin name function 1, 3 rfgnd rf ground is internally connected to the module screen and pin 6 (0v). these pins should be directly connected to the rf r eturn path - e.g. coax braid, main pcb ground plane etc. 2 rf out 50 rf output to the antenna 4 en pull high to enable transmitter (3v cmos logic ) 5 vcc 2.9 ? 15v dc power supply 6 0v ground 7 txd dc coupled input (3v cmos logic). r in = 100k notes : 1. en must not be left floating 2. pinout footprint is as ntx2. (like a tx1, but pc b is longer) 3. compatible with lmr0 and nrx0. 4. txd is actually a linear input, with self bias t o 1.5v 5. 27.095mhz is the default channel.
radiometrix ltd., NTX0/nrx0 data sheet page 3 nrx0 receiver 7 holes of 0.7mm dia pin spacing 2.54mm (0.1") 1 2 3 4 5 6 7 47mm 17mm 30.48mm (1.2") 8mm radiometrix nrx0 1 = rf in 2 = rf gnd 3 = rssi 4 = 0v 5 = vcc 6 = af 7 = rxd figure 3: nrx0 pin-out and dimension user interface ? nrx0 nrx0 pin name function 1 rf in 50 rf input from the antenna 2 rf gnd rf ground is internally connected to the m odule screen and pin 4 (0v). these pins should be directly connected to the rf r eturn path - e.g. coax braid, main pcb ground plane etc. 3 rssi received signal strength indicator with >60d b range. dc level between 0.5v and 2v 4 0v ground 5 vcc 2.9 ? 15v dc power supply (4.1 ? 15v for 50 a nd 100mw version) 6 af 500mv pk-pk audio. dc coupled, approx 0.8v bias 7 rxd received data output from the internal data s licer. the data is squared version of the audio signal on pin 6 and is true da ta, i.e. as fed to the transmitter. output is "open-collector" format with internal 10k pull-up to vcc (pin 5). suitable for bi-phase codes notes : 1. pinout is as nrx1, nrx2 and rx2a receivers 2. unlike other nrx family radios, the sense of af, relative to transmitter input, is not inverted 3. 27.095mhz is the default channel.
radiometrix ltd., NTX0/nrx0 data sheet page 4 absolute maximum ratings exceeding the values given below may cause permanen t damage to the module. operating temperature -10 c to +60 c storage temperature -30 c to +70 c NTX0 vcc, txd (pins 5,7) -0.3v to +16.0v en (pin 4) -0.3v to +vcc v rf out (pin 2) 50v @ <10mhz, +20dbm @ >10mhz nrx0 vcc, rxd (pins 7,9) -0.3v to +16.0v en, rssi, af (pins 4,5,8) -0.3v to +vcc v rf in (pin 1) 50v @ <10mhz, +13dbm @ >10mhz performance specifications: NTX0 transmitter (vcc = 3v / temperature = 20 c unless stated) general pin min. typ. max. units notes dc supply supply voltage for 10mw 5 2.9 3.0 15 v tx supply current @ 10mw 5 20 - ma supply voltage for 50mw 5 4.1 5.0 15 v tx supply current @ 50mw 5 50 - ma supply voltage for 100mw 5 4.1 5.0 15 v tx supply current @ 100mw 5 70 - ma antenna pin impedance 2 - 50 -  rf rf centre frequency - 27.095 - mhz 1 channel spacing - 10 - khz number of channels - 1 - rf power output 2 +9 +10 +11 dbm 2 rf power output 2 +16 +17 +18 dbm 2, 8 rf power output 2 +19 +20 +21 dbm 2, 8 spurious emissions 2 - - -40 dbm 7 adjacent channel tx power - -37 - dbm frequency accuracy - 1.5 khz 3 fm deviation (peak) - 2.0 - khz 4 baseband modulation type - fsk - f3d modulation bandwidth @ -3db 0 - 3 khz data rate - - 5 kbps nrz txd input level (logic low) 7 - 0 - v 5 txd input level (logic high) 7 - 3.0 - v 5 dynamic timing tx enable to full rf - - 5 ms notes: 1. available in 25khz channel steps on other custom frequencies in the 27mhz band 2. measured into 50 resistive load. 3. total over full supply and temperature range. 4. with 0v ? 3.0v modulation input. 5. to achieve specified fm deviation. 6. for 1v pk-pk signal biased at 1.4v 7. complies with spurious emission limits of etsi e n 300 220-1 8. for use in usa, australia, nz and only for model control in europe. the 100mw version is limited to 9v or 25% duty cycl e
radiometrix ltd., NTX0/nrx0 data sheet page 5 performance specifications: nrx0 receiver (vcc = 3v / temperature = 20 c unless stated) pin min. typ. max. units notes dc supply supply voltage 7 2.9 3.0 15 v supply current 7 - 12 - ma rf/if rf centre frequency 1,6 - 27.095 - mhz frequency accuracy 1, 6 - 1.5 - khz channel spacing 1, 6 - 10 - khz rf sensitivity @ 12db sinad 1, 6 - -115 - dbm 1 rssi range 1, 4 - 60 - db 2 blocking 1 - 85 - db image rejection 1 -45 - - db adjacent channel rejection 1 - -70 - db spurious response rejection 1 -45 - - db lo re-radiation 1 -65 - - dbm 3 baseband baseband bandwidth @ -3db 6 0 - 3 khz 2 data rate - - 5 kbps nrz af level 6 - 500 - mv p-p 4 dc offset on af out 6 - 0.8 - v distortion on recovered af 6 - 5 - % dynamic timing power up with signal present power up to valid rssi 5, 3 - 3 - ms power up to valid af 5,6 - 2 - ms power up to stable data 5, 7 - tba 10 ms signal applied with supply on signal to valid rssi 1, 3 - 2 - ms signal to valid af 1,6 - 1 ms signal to stable data 1, 7 - tba 5 ms 5 time between data transitions 7 0.1 - tba ms notes: 1. for 12 db sinad, 1khz mod, 2khz dev 2. see applications information for further details . 3. exceeds en/emc requirements at all frequencies. 4. for received signal with 2khz fm deviation 5. for 50:50 mark to space ratio (i.e. squarewave).
radiometrix ltd., NTX0/nrx0 data sheet page 6 applications information power supply requirements both modules have built-in regulators which deliver a constant 2.8v (4v in 50mw and 100mw version) to the module circuitry when the external supply volta ge is 2.9v or greater (4.1v in 50mw and 100mw version), with 40db or more of supply ripple reject ion. this ensures constant performance up to the maximum permitted rail, and removes the need for ex ternal supply decoupling except in cases where the supply rail is extremely poor (ripple/noise content >100mv pk-pk ). continuous operation of 100mw version above 9v supp ly is not recommended. the enable pin allows the tx module to be turned on or off under 3v logic control with a constant dc s upply to the vcc pin. the module current in power-down mo de is less than 1a. the enable pin should be tied directly to the vcc p in if this facility is not required. NTX0 modulation requirements the module is factory-set to produce the specified fm deviation with a txd input to pin 7 of 3v amplit ude, i.e. 0v ?low?, 3v ?high if the data input level is greater than 3v, a resis tor must be added in series with the txd input to l imit the modulating input voltage to a maximum of 3v on pin 7. txd input resistance is 100k to ground, giving typical required resistor values as follows: vcc series resistor 3v 3.3v 5v 9v - 10 k 68k 220k nrx0 received signal strength indicator (rssi) the nrx0 receiver incorporates a wide range rssi wh ich measures the strength of an incoming signal ove r a range of 55db or more. this allows assessment of link quality and available margin and is useful whe n performing range tests. the output on pin 3 of the module has a standing dc bias of <0.5v with no signal, rising to 2v at maxi mum indication. typical rssi characteristic is as shown below: fig.6: typical rssi response curve
radiometrix ltd., NTX0/nrx0 data sheet page 7 module mounting considerations the modules may be mounted vertically or bent horiz ontal to the motherboard. note that the components mounted on the underside of the NTX0 and nrx0 are r elatively fragile ? avoid direct mechanical contact between these and other parts of the equipment if p ossible, particularly in situations where extreme mechanical stresses could routinely occur (as a res ult of equipment being dropped onto the floor, etc) . good rf layout practice should be observed. 50 microstrip line or coax or a combination of both s hould be used to connect rf pin of the module to rf connecto r or antenna. it is desirable (but not essential) t o fill all unused pcb area around the module with ground plane . variants and ordering information the NTX0 transmitters and nrx0 receivers are manufa ctured on 27.095mhz as standard: NTX0-27.095-5 10mw transmitter NTX0-27.095-5-50mw 50mw transmitter NTX0-27.095-5-100mw 100mw transmitter nrx0-27.095-5 receiver subject to moq, other frequency variants can be sup plied to individual customer requirements in the 27 mhz licence exempt srd / model control band. i.e. 10mw 26.957 - 27.283mhz non-specific short range devices (srd) 100mw 26.995, 27.045, 27.095, 27.145, 27.195 mhz m odel control
radiometrix ltd hartcran house 231 kenton lane harrow, middlesex ha3 8rp england tel: +44 (0) 20 8909 9595 fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com copyright notice this product data sheet is the original work and co pyrighted property of radiometrix ltd. reproduction in whole or in part must give clear acknowledgement to the copyright owner. limitation of liability the information furnished by radiometrix ltd is bel ieved to be accurate and reliable. radiometrix ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. radiometrix lt d does not assume any liability arising from the application or use of any product or circuit descri bed herein, nor for any infringements of patents or other rights of third parties which may result from the u se of its products. this data sheet neither states nor implies warranty of any kind, including fitness for any particular application. these radio devices ma y be subject to radio interference and may not function as intended if interference is present. we do not recommend their use for life critical applications. the intrastat commodity code for all our modules is : 8542 6000 r&tte directive after 7 april 2001 the manufacturer can only place finished product on the market under the provisions of the r&tte directive. equipment within the scope of the r&tte directive may demonstrate compliance to the essential requirements specified in article 3 of the directive, as appropriate to the particula r equipment. further details are available on the office of comm unications (ofcom) web site: http://www.ofcom.org.uk/ information requests ofcom riverside house 2a southwark bridge road london se1 9ha tel: +44 (0)300 123 3333 or 020 7981 3040 fax: +44 (0)20 7981 3333 information.requests@ofcom.org.uk european communications office (eco) peblingehus nansensgade 19 dk 1366 copenhagen tel. +45 33896300 fax +45 33896330 ero@ero.dk www.ero.dk


▲Up To Search▲   

 